COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS
Service Handbook
PRINTED IN THE U.S.A. 0914 329298-000
500 Tennessee Waltz Parkway
Ashland City, TN 37015
FOR MODELS:
SUF 60120 THRU SUF 100250
SUF 119300 THRU SUF 119500
SERIES 200/201
INSTALLATION CONSIDERATIONS - PRE SERVICE CHECKS -
CONSTRUCTION - OPERATION & SERVICE - TROUBLESHOOTING
SERVICING SHOULD ONLY BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN
Page view 0
1 2 3 4 5 6 ... 55 56

Summary of Contents

Page 1 - Service Handbook

COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERSService HandbookPRINTED IN THE U.S.A. 0914 329298-000500 Tennessee Waltz ParkwayAshland City, TN 37015FOR

Page 2 - TABLE OF CONTENTS

9Servicing should only be performed by a Qualied Service Technician5. When installing multiple water heaters in the same gas supply system it is rec

Page 3 - INTRODUCTION

10Servicing should only be performed by a Qualied Service Technician7. Record the supply gas pressure.8. Use the Enable/Disable Switch located on t

Page 4 - INSTALLATION CONSIDERATIONS

11Servicing should only be performed by a Qualied Service Technician2. BLOWER OPERATION ERROR CHANGE BACK ADVANCEDBlower Operation ErrorFault occurr

Page 5 - FEATURES AND COMPONENTS

12Servicing should only be performed by a Qualied Service TechnicianPRESSURE SWITCH TESTSComplete pressure switch testing involves three procedures:•

Page 6

13Servicing should only be performed by a Qualied Service TechnicianCONTINUITY TEST DURING OPERATIONThis test is performed while the Combustion Blowe

Page 7

14Servicing should only be performed by a Qualied Service Technician• Blower Prover Switch - normally open contacts, close on a rise in pressure.•

Page 8 - FAULT AND WARNING CODES

15Servicing should only be performed by a Qualied Service TechnicianBlocked Air Intake: Note these are negative pressures; in a vacuum. If the pressu

Page 9 - SUPPLY GAS REGULATOR

16Servicing should only be performed by a Qualied Service Technician3. BLOWER PROVER OPEN CHANGE BACK ADVANCEDBlower Prover OpenFault occurred 2 min

Page 10 - GAS PRESSURE TEST

17Servicing should only be performed by a Qualied Service Technician4. IGNITION FAILURECHECK/ REPAIR• Determine whether or not the burner is ignitin

Page 11

18Servicing should only be performed by a Qualied Service Technician• Reinsert connector on Flame Sensor and make sure the electrical connection is

Page 12 - Blower Operation Error

1TABLE OF CONTENTSINTRODUCTION ...2Qualications ...

Page 13 - PRESSURE SWITCH TESTS

19Servicing should only be performed by a Qualied Service Technician• Remove and reinsert the circuit board end of the Gas Control Valve connector.

Page 14

20Servicing should only be performed by a Qualied Service Technician5. BLOCKED AIR INTAKE CHANGE BACK ADVANCEDBlocked Air IntakeFault occurred 2 min

Page 15 - PRESSURE SWITCH SETTINGS

21Servicing should only be performed by a Qualied Service Technician6. BLOCKED EXHAUST CHANGE BACK ADVANCEDBlocked ExhaustFault occurred 2 mins agoR

Page 16

22Servicing should only be performed by a Qualied Service Technician7. FLAME SENSOR ERROR CHANGE BACK ADVANCEDFlame Sensor (error)Fault occurred 1 m

Page 17 - Blower Prover Open

23Servicing should only be performed by a Qualied Service TechnicianGAS CONTROL VALVE VOLTAGE TESTS1. The animated Gas Control Valve Status Ic

Page 18 - 4. IGNITION FAILURE

24Servicing should only be performed by a Qualied Service TechnicianFLAME SENSORIgnition of the Burner is controlled electronically. The principle of

Page 19

25Servicing should only be performed by a Qualied Service TechnicianFLAME SENSING CURRENT TESTDuring the heating cycle the ame sensing current is no

Page 20

26Servicing should only be performed by a Qualied Service Technician8. NO WATER CHANGE BACK ADVANCEDNo WaterAlert:Alert occurred 2 mins agoNo water

Page 21 - Blocked Air Intake

27Servicing should only be performed by a Qualied Service TechnicianCLEANING METHOD:If corrosion is present on the air side of the anode, use a wire

Page 22 - Blocked Exhaust

28Servicing should only be performed by a Qualied Service Technician9. ANODE SHORTED CHANGE BACK ADVANCEDAnode ShortedAlert:Alert occurred 0 mins ag

Page 23 - Flame Sensor (error)

2Servicing should only be performed by a Qualied Service TechnicianINTRODUCTIONThis Service Handbook covers the water heater Model and Series numbers

Page 24

29Servicing should only be performed by a Qualied Service Technician10. TEMPERATURE PROBE SHORT (UPPER OR LOWER) CHANGE BACK ADVANCEDUpper Temp Prob

Page 25 - (MUST BE GROUNDED)

30Servicing should only be performed by a Qualied Service TechnicianIf the resistance of the Temperature Sensor is below 390 ohms the Control System

Page 26 - FLAME SENSING CURRENT TEST

31Servicing should only be performed by a Qualied Service TechnicianResults/Actions• If the ohm meter shows continuity (closed circuit) between the

Page 27 - No Water

32Servicing should only be performed by a Qualied Service Technician11. TEMPERATURE PROBE OPEN (UPPER OR LOWER) CHANGE BACK ADVANCEDLower Temp Probe

Page 28

33Servicing should only be performed by a Qualied Service TechnicianVENTINGThis section of the Service Handbook is not a complete venting installatio

Page 29 - Anode Shorted

34Servicing should only be performed by a Qualied Service TechnicianINTAKE AIR CONNECTIONThe intake air connection has a screen and a hose barb insta

Page 30 - Upper Temp Probe (Short)

35Servicing should only be performed by a Qualied Service TechnicianELECTRICAL CONNECTIONS – ALL MODELSThe water heaters covered in this Service Hand

Page 31 - ECO CONTINUITY TEST

36Servicing should only be performed by a Qualied Service Technician5. Connect the ground wire from the power supply to the grounding lug inside the

Page 32

37Servicing should only be performed by a Qualied Service TechnicianINSTALLATION CHECK LISTThe list below represents some of the most critical instal

Page 33 - Lower Temp Probe (Open)

38Servicing should only be performed by a Qualied Service TechnicianOPERATION AND SERVICEHOW IT WORKSThis section of the Service Handbook will cover

Page 34 - GENERAL VENTING INFORMATION

3Servicing should only be performed by a Qualied Service TechnicianINSTALLATION CONSIDERATIONSThis section of the Service Handbook covers some

Page 35 - INTAKE AIR CONNECTION

39Servicing should only be performed by a Qualied Service TechnicianService Note: The 5 pin PWM signal plug MUST remain plugged in to the 5 pin socke

Page 36 - POWER SUPPLY CONNECTIONS

40Servicing should only be performed by a Qualied Service TechnicianBLOWER SPEED CONTROL – SUF 119300 THRU 119500The CCB monitors a feedback signal f

Page 37 - POWER SUPPLY TEST

41Servicing should only be performed by a Qualied Service TechnicianVARIABLE FREQUENCY DRIVE – SUF 119300 THRU 119500The SUF 119300 - 119500 models h

Page 38 - INSTALLATION CHECK LIST

42Servicing should only be performed by a Qualied Service TechnicianBURNER ASSEMBLYThe Burner is a radial design burner with a steel ber jacket on t

Page 39 - OPERATION AND SERVICE

43Servicing should only be performed by a Qualied Service TechnicianCOMBUSTION BLOWER AND BURNER REMOVAL/ INSTALLATION INSTRUCTIONSRefer to the Combu

Page 40

44Servicing should only be performed by a Qualied Service TechnicianSPARK IGNITERThe water heaters covered in this Service Handbook use a Spark Ignit

Page 41

45Servicing should only be performed by a Qualied Service TechnicianThe Control System is programmed to start sparking a few seconds before the Gas C

Page 42

46Servicing should only be performed by a Qualied Service TechnicianGAS ORIFICE - SUF 119300 THRU 119500 MODELSRefer to Orifice Chart below for corre

Page 43 - BURNER ASSEMBLY

47Servicing should only be performed by a Qualied Service TechnicianCCB (CENTRAL CONTROL BOARD)The CCB is a printed circuit board mounted inside a pr

Page 44 - INSTRUCTIONS

48Servicing should only be performed by a Qualied Service TechnicianCCB COVER REMOVAL AND REPLACEMENTThe cover on the CCB enclosure must be removed f

Page 45 - SPARK IGNITER

4Servicing should only be performed by a Qualied Service TechnicianFEATURES AND COMPONENTSCOMBUSTION BLOWER & BURNER ASSEMBLYAir Intake AssemblyL

Page 46

49Servicing should only be performed by a Qualied Service TechnicianCCB CIRCUIT BOARD LAYOUT11121J16J5J3J13J4J17J10J9J14J15J1J6J121111111111112222222

Page 47

50Servicing should only be performed by a Qualied Service TechnicianCCB CONNECTION IDENTIFICATIONJ1 Socket - High Voltage InPIN # DESCRIPTION1 Ground

Page 48 - CCB (CENTRAL CONTROL BOARD)

51Servicing should only be performed by a Qualied Service TechnicianJ14 Socket - Limit StringPIN # DESCRIPTION1 Anode2 Grounding3 Flame Sensor4 Conde

Page 49

52Servicing should only be performed by a Qualied Service TechnicianWIRING DIAGRAM – SUF 60120 THRU 100250

Page 50 - CCB CIRCUIT BOARD LAYOUT

53Servicing should only be performed by a Qualied Service TechnicianWIRING DIAGRAM – SUF 119300 THRU 119500

Page 51 - CCB CONNECTION IDENTIFICATION

54Servicing should only be performed by a Qualied Service TechnicianCONTROL OVERVIEWInteraction with the water heater controller is through an UIM di

Page 52 - PIN # DESCRIPTION

COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERSVisit the "Information Central" link of www.statewaterheaters.com for a listing of available Ser

Page 53

5Servicing should only be performed by a Qualied Service TechnicianTOP VIEW: SUF 60120 - 100250 MODELSBlocked Exhaust SwitchPowered Anode (Short, SUF

Page 54

6Servicing should only be performed by a Qualied Service TechnicianSEQUENCE OF OPERATION FLOW CHARTYES NOWater is heated to set point24 Volt Gas Valv

Page 55 - CONTROL OVERVIEW

7Servicing should only be performed by a Qualied Service TechnicianFAULT AND WARNING CODES1. LOW GAS PRESSURE CHANGE BACK ADVANCEDLow Gas PressureFa

Page 56 - State Water Heaters

8Servicing should only be performed by a Qualied Service TechnicianGAS SUPPLY SYSTEMSLow pressure building gas supply systems are defined as those sy